Viking Control Board DUPCB10 or Circuit Board DUMSCB10 Slave for G5 and X9
The Gate Operator requires a single phase AC line to operate and charge the batteries.
A Master/Slave control board is available, when required, to run two gate operators in
synchronous mode.
Vehicle loop detectors must be installed to decrease the possibility of vehicle entrapment on the gate. The
SECONDARY ENTRAPMENT PROTECTION like the edge sensor and the photoelectric beam MUST BE PART OF
EVERY SINGLE INSTALLATION to prevent pedestrian or animal entrapment.
Viking control board or Viking Circuit Board provides two modes of operation that a radio receiver can control the
gate.
External supply for the magnetic lock must be provided. This will prevent rapid drainage of the battery in the event of
power failure.
External supply for the solenoid connection must be provided. This will prevent rapid drainage of the battery in the
event of power failure.
The guard station provides control of the gate operator to open, stop and close the gate.
The Obstruction Sensor detects obstructions in the path of the traveling gate. The Trim Pot for the Obstruction
Sensor adjusts the sensitivity level that triggers the Sensor.
The gate operator contains a unique design that allows the user to move the gate manually in case of power failure.
There are three levels of force required to move the gate manually.
Minimum Force:
By removing the wire-jumper plug from the “Fail Safe/Secure” connector: The gate can be move manually with
relative low amount of force.
Maximum Force:
By inserting the wire-jumper plug into the “Fail Safe/Secure” connector: The gate can still be move by hand with
relative high amount of force.
Manual Operation Locked
By removing the “Break Release Pin” from the operator: The gate can’t be moved manually.
The Hold Open Timer function holds the gate at the open position for a predetermined amount of time, prior to closing automatically. Set the Timer to the desired time, from 1 to 60 seconds.
Setting the Overlap Delay Pot to “0” will cause the master and the slave units to open and close at the same time |