Ramset Main Circuit Board Electronic Control Board Intelligate
|
|
|
Ramset Main Circuit Board Electronic Control
Board Intelligent:
Ramet Intelligent Circuit Board features: Re-programmable
microprocessor: Allows control boards to be updated. LED
diagnostics: LED (red lights) show the status of the control
board at all times. 3-Button station: Easy connection plug
(included) for 3-button stations. Status relays: Triggers
relays when the gate is fully open or fully closed. Plug-in
loop detectors: Allows ILD-24 plug-in loop detectors (sold
separately) to be used, eliminating messy wire
connections. The control board is powered by a 24VAC
transformer (sold separately). This allows no necessary
board modifications between 110VAC and 220VAC
single-phase applications.
Regular Price: $579.00
Our Price: $417.50
Ramset Main Circuit Board Replacement Electronic Control Board Intelligate
|
Ramset Intelligent control board works with all of Ramset slide, swing and overhead vehicular gate
operators. It is controlled by a programmable microprocessor that reads and precisely executes all
functions of the control board. The control board is powered by a separate mounted 24VAC
transformer. This allows no necessary board modifications between 110VAC and 220VAC
single-phase applications.
Ramset Intelligent Control Board features:
Reprogrammable Microprocessor: Allows control boards to be updated.
LED diagnostics: LED (red lights) show the status of the control board at all times.
3-Button Station: Easy connection plug (included) for 3-button stations.
Status Relays: Triggers relays when the gate is fully open or fully closed.
Plug-in Loop Detectors: Allows ILD-24 plug-in loop detectors (sold separately) to be used, eliminating
messy wire connections.
Ramset Intelligent Circuit Boards functions include:
Automatic Close Timer: Automatically closes the gate after 0 - 60 seconds after the gate fully opens
and all of the safety devices are cleared.
Pre Warning: Adds a 3 second delay before the gate moves in any direction. During this 3 second
delay the PREWARN relay maintains a closed contact. This allows an alarm or light to be connected
to warn when the gate is about to move.
Constant Warning: Triggers the PREWARN relay to maintain a closed contact while gate is in motions.
This allows an alarm or light to be connected to show when the gate is moving.
Secure Close: When power is lost, then regained, the control board checks the status of the gate. If
the gate is open and the safety devices are cleared, the gate will automatically close.
Radio Cycle: Allows the gate to be stopped at any time with the remote control. Then reverse with
another command.
One Pass: Closes the gate immediately after the safety devices are cleared. If another car triggers a
safety device the gate will stop but not open until a valid open signal is received.
Open & Close Delay: Adds a 1 second delay before the gate opens and/or closes.
Left/Right: With a flip of a switch, the logic of the control board changes from a left hand operation to
a right hand operation.
Master/Slave: Synchronizes two gates to work together in a bi-parting installation.
ERD (Electronic Reversing Devices): Automatically adjusts the sensitivity of the operator to the size of
the gate. |