                          | Eagle Diamond Board, Eagle Main Control Board for Eagle Gate Operators |  
                      |  |  | The Eagle Diamond   Control Board is for all Eagle Gate Operators ( Gate Openers ) whether   you have a Sliding Gate Opener Or A swing Gate Opener. 
                        If is a Eagle The   control Board Should be The Diamond Board. Inspect the 
                        Board carefully   there is no returns on Electronic Equipment.
 
 Regular Price: $550.00
 Our Price: $395.00
 Eagle Diamond Main Control, Eagle Electronic Board for Gate Openers     
   Eagle 1 Circuit Board, Eagle 2 Control Board |  All Eagle   gate operators use the state of the art Eagle Diamond Control   Board.
 This   board includes many new features that cannot be found on other   gate 
                        operators.
 The Feature Selector uses an eight station switch that   allows selection of the standard features and customized 
                        installation   settings. The switch description is as follows:
 
 Switch 1 = Slave/Master -   Sets the operator to work as a Master or a Slave.
 Switch 2 = Gate Opening   - Designates left or right opening.
 Switch 3 = Motor Brake - If the "on"   position is selected, the gate will stop instantly when on the limit switches.   This is 
                        useful on uphill/downhill applications and on all Fail-Safe   operators.
 Switch 4 = Reverse Loop - Sets the reverse loop to be   "normally" open or to "normally" close. It is useful in Fail-safe 
                        applications.
 Switch 5 = One Pass (on/off) - This tailgating feature   works with the safety loop to allow only one car to pass. After the 
                        car   passes, the gate closes instantly. If a second car approaches the gate stops.   The operator resumes closing after 
                        the car leaves.
 Switch 6 =   Stop-Reverse - This radio feature allows the transmitter to work as a three   button station and is useful for a 
                        partial opening. If selected, the   first command will open the gate, the second will stop the gate, and the third   will
                        close the gate.
 Switch 7 = Alarm Reset (on/off) - If the "on"   position is selected (after five minutes "shut down" time period) the 
                        operator will reset and any input will be accepted. Normally, the power   must be turned off to reset.
 Switch 8 = Close Timer (on/off) - Sets the   timer to close on the "on" or "off" position.
 
 The Eagle Diamond Control   Board uses an unique Master/Slave system that requires only two wires. In   addition, the
 Diamond board has global inputs. These inputs give the   installer the option to connect accessories to the Master or to
 the   Slave. Another stand out feature is the "open and close delay", this function is   easily selected on the Slave board.
 On the Master Control one has the option   to select the following features: one pass mode, stop-reverse mode, alarm
 reset mode, and close timer. The Slave Control was uniquely designed to   communicate to the master board
 all of the delay functions.
 
 Switch 5 =   Open Delay Slave (on/off) - Selecting the dipswitch to the "on" position delays   the slave operator by one 
                        second on the open cycle. This is useful with   a magnetic lock application.
 Switch 6 = Open Delay Master (on/off) -   Selecting the dipswitch to the "on" position delays the mast operator by one 
                        second on the open cycle. This is useful with a magnetic lock   application.
 Switch 7 = Close Delay Slave (on/off) - Selecting the   dipswitch to the "on" position delays the slave operator by 1-6 
                        seconds   on the close cycle. You can set the delay time desired by adjusting the delay   potentiometer.
 Switch 8 = Close Delay Master (on/off) - Selecting the   dipswitch to the "on" position delays the master operator by 1-6 
                        seconds on the close cycle. You can set the delay time desired by adjusting   the delay potentiometer.
 
 The Eagle Diamond Control Board uses LEDs to   indicate the status of the inputs and outputs of the gate operator.
 
 The   Diamond board has several unique safety features. In case of overload, if the   motor reaches the stall amp for 3 
                        seconds, it will automatically shut   down. If the gate hits an obstruction while closing, it will re-open. If it hits   an 
                        obstruction while opening, it will stop, reverse 6 inches and stop   again. The sensitivity is adjustable separately for the 
                        open and close   cycle. If the gate hits an object twice while closing or opening, the system   will shut down for 5 minutes. 
                        On the Diamond board you have two options   of reset mode. Selecting the "off" position will require a manual reset of 
                        the board if the previous happens. However, by selecting the "on" position,   the system will automatically reset itself. 
                        Global Inputs allow the installer   the option to connect accessories to the Master or to the Slave - key switch,   keypad, 
                        exit loop, phantom loop, reverse loop, edge sensor, open, stop,   and close. The Receiver terminal is mounted on the 
                        control box for easy   installation and is pre-wired for a 3-wire or a 4-wire receiver. The Diamond   board's Outputs 
                        include on board 24VDC for MAG Lock, alarm, and 24VAC   auxiliary power. The Diamond board has an Adjustable
 Timer that can be   set from 1 to 6 seconds. The maximum run time is 6 seconds, after which if the   gate hasn't 
                        reached the open or close limit it will automatically shut down.
 |